“Providing healthy clean drinking water Blog without chemicals”

Case: Government Drinking Water Project

Swiss Cleanwater Group have helped with an Indonesian Government sponsored drinking water program.

More...
Planning for the future: How to use our water resources more efficiently

Swiss Cleanwater Group will be presenting their thoughts on water treatment opportunities moving forward in 2013, and the challenges that…

More...
Having problems with Manganese?

Most of the municipal corporations are already made aware about the presence of manganese in drinking water by now. However,…

More...
The SCG Advantage

Eight reasons as to why the Swiss Cleanwater Machines are a better solution to your water treatment needs.

More...
Frontpage Slideshow | Copyright © 2006-2011 JoomlaWorks, a business unit of Nuevvo Webware Ltd.

How to Address Biofilm Formation in Chemical-Free Filtration Distribution Pipes

Chemical-free water treatment can reduce reliance on chlorine, coagulants and other consumables while removing contaminants such as manganese, arsenic, bacteria, pesticides and uranium. However, the absence of disinfectant residual in a distribution network changes the way operators must control microbial growth. Biofilm can develop inside pipes, valves, storage tanks and fittings even when water leaving the treatment unit meets the required quality target.

A reliable strategy combines sound filtration, hygienic pipework design, controlled hydraulics, regular monitoring and physical cleaning. For Australian water suppliers, farms, industrial sites and remote facilities, this approach is particularly useful where chemical storage is impractical, water is scarce, and systems must operate efficiently through hot weather and variable demand.

Why biofilm develops after filtration

Biofilm is a structured layer of microorganisms attached to a wet surface and surrounded by a protective matrix. In a distribution pipe, it can form when small amounts of biodegradable organic matter, fine particles or residual nutrients pass through the treatment stage. The organisms attach to the pipe wall, multiply and become harder to remove than free-floating bacteria.

Low flow is a major contributing factor. Dead legs, oversized mains, rarely used outlets and poorly drained branches provide the residence time needed for microbial attachment. Warm conditions accelerate the process, making temperature a practical concern in areas such as Brisbane, Perth and regional New South Wales during summer. Transparent sections exposed to sunlight can also encourage biological growth.

Biofilm is not always visible. A pipe may appear clean while releasing bacteria, tastes, odours or particles into the water. Sloughing can produce intermittent test results, with a clear sample followed by an elevated bacterial count after hydraulic disturbance. This is why testing only at the treatment outlet does not provide a complete picture of downstream water quality.

Design the distribution system to limit growth

The best opportunity to control biofilm is during system design. Keep pipe runs as direct as possible, eliminate unused branches and avoid fittings that create stagnant pockets. Looped networks can improve circulation, but they must be hydraulically balanced so that water does not remain motionless in isolated sections. Storage tanks should have appropriately located inlets and outlets, covered access points, screened vents and a means of complete drainage.

Pipe diameter should match realistic demand rather than a short peak-flow event. An oversized pipe can reduce velocity and increase water age, while an undersized pipe can create excessive pressure loss and operational problems. Automated flushing points, drain valves and sample taps make it easier to remove stagnant water without dismantling the network.

Material selection also matters. Smooth, approved materials with low surface roughness are generally easier to maintain than porous or heavily scaled surfaces. Joints should be installed carefully, because damaged seals, uneven couplings and construction debris provide attachment sites. In livestock, agricultural and mining installations, the distribution layout should account for dust, heat, long branch lines and periods when parts of the site are unoccupied.

Strengthen the treatment barrier

A chemical-free treatment train should prevent as much particulate and biodegradable material as possible from reaching the distribution system. Pre-filtration can capture suspended solids, while specialised media can target dissolved contaminants. Correct backwashing is essential: a filter that is not adequately cleaned may become a source of trapped solids and microbial growth rather than a protective barrier.

The treatment process must be matched to the raw water. Groundwater containing iron and manganese may require oxidation and media filtration, while arsenic or uranium removal can depend on adsorption and carefully selected specialty media. Understanding how contaminants interact with treatment media helps operators avoid breakthrough and maintain stable downstream conditions; this adsorption science resource provides useful technical context.

Physical disinfection can complement filtration without adding a chemical residual. Ultraviolet treatment can inactivate microorganisms at the point of production, provided the water has suitable clarity and the lamp receives regular maintenance. UV does not remove organisms from downstream pipe walls, so it should be combined with good network hygiene, adequate circulation and a documented response plan for contamination events.

Where appropriate, membrane filtration, ozone or other non-chemical technologies may provide additional barriers. The correct selection depends on raw-water quality, flow, energy availability and the required level of protection. A treatment supplier should assess the complete system rather than treating the filter as an isolated piece of equipment.

Control flow, storage and operating routines

Water age is a useful operational indicator. Record the time water spends in tanks and distribution sections, then identify locations where it remains unused for several days. Scheduled flushing can reduce accumulation in low-use branches, but it should be controlled so that it does not waste valuable water or disturb settled material throughout the network.

Storage tanks require particular attention. Roofs, hatches and vents should prevent contamination from dust, insects, birds and surface runoff. Tanks need inspection access, level controls and a cleaning schedule based on risk and observed sediment rather than an arbitrary calendar alone. In remote Australian communities and mobile applications, remote level and turbidity monitoring can help identify problems before a site visit is possible.

Backwashing and rinse water should be managed so that it cannot flow back into treated-water lines. Check valves, air gaps and correct pipe separation reduce the risk of cross-connection. Maintenance staff should use clean tools and follow hygienic procedures when opening filter housings, sample points or tank access covers.

For farms and livestock operations, demand can change sharply between watering cycles. For swimming pools, buildings and commercial premises, unused areas may remain isolated during holidays or seasonal closures. A written start-up and shutdown procedure should cover flushing, inspection, sampling and the safe return of each section to service.

Monitor, clean and verify performance

A biofilm management programme should use trend data rather than isolated results. Useful measurements include turbidity, temperature, pH, conductivity, pressure loss, flow, total bacterial counts and, where relevant, E. coli or other indicators required by the local water-quality plan. Samples should be collected at the treatment outlet, storage tank, farthest outlet and locations with a history of stagnation.

A sudden pressure change may indicate fouling, scaling or a partially blocked section. A rise in turbidity after a high-flow event can signal biofilm detachment or sediment movement. Operators should record the location, time, flow conditions and maintenance history for each result. This information helps distinguish a treatment problem from a distribution problem.

When cleaning is required, isolate the affected section, remove deposits using an appropriate mechanical method and flush until water quality stabilises. Non-chemical systems still need physical maintenance. Pigging may suit some larger, purpose-built mains, while smaller systems may require brushing, flushing or removal and cleaning of fittings. The selected method must be compatible with the pipe material and downstream equipment.

Corrective work should be verified through repeat sampling and inspection. If growth returns quickly, look for the underlying cause: excessive water age, a damaged filter, inadequate backwash, tank contamination, warm pipework or a dead leg. Simply cleaning the affected section without correcting the hydraulic or treatment condition usually provides only temporary relief.

Adapt the approach to Australian conditions

Australian operators must consider the local regulatory setting, climate and practical access to service support. Drinking-water responsibilities can differ between states and territories, while remote projects may have limited laboratory access and long transport distances. A system intended for a municipal supply in Melbourne may require a different monitoring and maintenance arrangement from one serving a cattle station in Queensland or a mining camp in Western Australia.

Heat management is important in exposed pipework and tanks. Shading, insulation, buried lines and suitable tank placement can reduce temperature rise, especially where water is stored for extended periods. Bushfire recovery, flooding and cyclone conditions may also introduce sediment or contamination into source water, requiring a documented contingency plan and additional inspection after an event.

Local procurement and serviceability should influence equipment selection. Replacement UV lamps, filter media, valves and monitoring instruments need to be available within a practical timeframe. Operators can review the complete process, site conditions and maintenance requirements with a specialist by using the meeting request page, particularly when planning a new installation or upgrading an existing network.

For councils, agriculture, industry and defence applications, the most resilient solution is usually a layered one: protect the source, remove contaminants effectively, limit water age, maintain hygienic storage and verify performance at representative points. This approach supports chemical-free operation without treating the distribution network as maintenance-free.

A well-designed programme turns biofilm control into a routine water-quality task rather than an emergency response. Review pipe layouts, inspect storage and filtration equipment, measure conditions at distant outlets, and establish flushing and cleaning procedures suited to the site. Speak with Swiss Cleanwater Group about a treatment and distribution strategy designed for the source water, operating environment and service obligations of your Australian project.

SCM 24

Swiss Cleanwater Group Machine 24
Cleans 24.000 liters per day

SCM 60

Swiss Cleanwater Group Machine 60
Cleans 60.000 liters per day
Video: How it works

Water Cleaning Systems & How They Work

The SCG Advantage

Our market-leading, water cleaning solutions have many advantages. To read more click the items below:

No Chemicals

Our machines and technology does not use any chemicals, at all.

Read more...

No Waste Water

Our machines do not waste any water. Yield = 100%.

Read more...

Low energy use

Uses 50 times less energy than a Reverse Osmosis Machine.

Read more...

Low ownership cost

Lower maintenance and operation costs due to our technology.

Read more...

Easy to install

Simple "plug and play" installation makes for easy deployment.

Read more...

Extremely compact

A compact system, contained in an easy to transport cabinet.

Read more...

Outperforms R.O.

SCG technologies outperform Reverse Osmosis systems.

Read more...

Faster ROI

Get a faster Return on Investment with our systems.

Read more...